Skip to content

Tycon Power 48V 120W DIN Rail Industrial Power Supply

PSDIN-48-120W by TYCON Systems
Sold out
Original price $84.95 - Original price $84.95
Original price $84.95
$84.95
$84.95 - $84.95
Current price $84.95

Tycon Power PSDIN Series of Industrial DIN Rail mount high efficiency switching power supplies operate over a wide temperature range of -40°C to +70°C. There are two models to supply 120W or 240W. The input is 90 to 264VAC auto-ranging with wire terminal connections. The output is 48VDC nominal with an adjustment range from 47VDC to 56VDC. There is a switch for single or parallel operation. There is an alarm output to provide a dry contact closure to trigger an alarm if the DC output fails, like during a grid power failure. The relay is closed when DC output is normal and open when DC output is in fault condition due to overload or safety shutdown.


Features
  • High Power and rugged design
  • Short Circuit, Over-Voltage, Over-current Protection
  • 90-264VAC Auto Ranging Input
  • 47~56VDC Adjustable Output
  • -40°C to +70°C Operating Temperature
  • Supports Parallel Operation
  • Dry Contact DC Alarm
Applications
  • Powering PoE Switches
  • IP Phone and Security Camera Systems
  • Telecommunications
Specifications
  • Input Operating Range: 90-264VAC ; 47-63Hz
  • Input In-rush Current: 35A Max
  • Input Current: 2.2A @ 115VAC ; 1.10A @ 230VAC
  • Output Voltage: 47~ 56VDC (adjustable)
  • Cont. Load Current: 2.5A
  • Maximum Output Power: 120W
  • Peak Power (10sec @ 220VAC): 180W
  • Line Regulation: +/- 0.5%
  • Load Regulation: +/- 1%
  • Voltage Overshoot: <5%
  • Ripple / Noise: 100mV Peak
  • Efficiency: 90% Minimum
  • Dielectric Strength: 1500V rms , 1 min, 10mA Max
  • Insulation Resistance: 10M Ohms
  • Protection: Short Circuit, Over-Voltage, Over-Current, Over Power
  • Alarm Output (“DC” and “OK”): 1A @ 30VDC, 0.5A @ 125VAC. DC OK = Closed, DC Fault = Open
  • Safety Standards: GB4943 / EN60950-1
  • EMI Standards: FCC PART 15 CLASS B, EN55022, EN55024
  • Harmonic Current EN61000-3-2 Class D
  • EMS: EN61000-4-x Level 3&4
  • Operating Temp: -40°C to 70°C (-40°F to 158°F)
  • Operating Humidity: 5% to 95% non- condensing
  • Storage Temp: -40°C to 85°C (-40°F to 185°F)
  • MTBF: 200,000hrs
  • Altitude: 2000m (6562ft)
  • Vibration: 10-500Hz 2G 10min Sweep, 20G Surge 11ms
  • Case Size: 135 x 121 x 40mm (5.3 x 4.8 x 1.6”)
  • Weight: 0.59 Kg (1.3Lb)
  • Warranty: 3 Years
Product Includes
(1) Tycon Power DIN Rail Power Supplies

(1) User Manual